The One Big Beautiful Bill Act (OBBBA) terminated the federal Investment Tax Credit (ITC) for solar on a fixed schedule. It did not terminate the credit for energy storage. Batteries, standalone or paired with solar, keep the full Section 48E credit for projects that begin construction through 2033, with a phase-down after. For commercial building owners, that single distinction decides what the federal government is still willing to co-invest in after December 31, 2027, and it happens to be the technology that attacks the fastest-growing lines on the electric bill.

The short version

  • Energy storage remains eligible for the 30% federal Section 48E credit for projects beginning construction through 2033, with the same 10% bonus adders for domestic content and energy communities. The phase-down starts in 2034. Standalone batteries qualify; no solar required.
  • A battery attacks the two bill lines solar alone cannot fully reach: demand charges, set by a building’s single highest 15-minute draw each month, and capacity tags, set by its draw during a handful of grid-wide peak hours each summer.
  • The Northeast states where Plankton Energy operates each have a program that pays storage to perform or are building one: Massachusetts through ConnectedSolutions and Clean Peak, Connecticut through Energy Storage Solutions, New York through its retail storage incentive, and New Jersey through the Garden State Energy Storage Program, whose distributed phase is still in the proposal stage.
  • Solar and storage together made up 91% of new grid capacity added in the United States in the first quarter of 2026, according to SEIA. Grid operators are planning around batteries because they are among the fastest resources to build.
  • For owners racing the 2027 solar window, adding storage keeps a federal credit in the capital stack after the solar credit is gone. For owners who already have solar, a standalone battery is a second, independent federal incentive.

What Congress ended, and what it kept

OBBBA, signed July 4, 2025, set a termination schedule for the solar credit: projects without a documented construction start by July 4, 2026 must be placed in service by December 31, 2027 to claim it. Storage was carved out. Under Section 48E, energy storage technology is its own qualifying category, and OBBBA left its credit on a longer timeline: full value for projects beginning construction through 2033, then 75% in 2034, 50% in 2035, and zero after.

Timeline comparing the Section 48E credit for commercial solar, ending December 31, 2027, with energy storage, full value through 2033

Three rules still apply. Projects of 1 megawatt or more must meet prevailing wage and apprenticeship requirements to claim the full 30% rather than a 6% base. Projects beginning construction in 2026 or later must satisfy the new foreign-entity sourcing rules, which set a minimum share of equipment cost that cannot come from prohibited foreign entities, and for storage that required share starts higher than it does for solar. Finally, the credit is taken on the storage system’s cost basis, so a battery should be sized for the building’s real load profile, not by rule of thumb.

The practical result is a federal incentive that outlives the solar credit by six years. It is worth building the capital stack around.

The two bill lines solar cannot finish

Commercial electric bills carry three kinds of charges. Energy (the kilowatt-hours consumed) is the one most owners think about, and solar attacks it directly. The other two are set by when and how hard a building draws, and they are where the money has been moving. For the full anatomy of a commercial bill, see how electricity rates are determined.

Demand charges are billed in dollars per kilowatt, based on the single highest 15-minute interval of the month. On commercial tariffs in New Jersey, New York and Massachusetts they often run $10 to $30 per kilowatt per month, depending on utility and rate class. A building that spikes to 800 kilowatts for fifteen minutes on one July afternoon pays for that spike all month. Solar lowers the spike only if the sun is out at that exact moment. On a cloudy afternoon, during an evening peak, or at a morning start-up load before the array is producing, solar does not reduce demand.

Capacity tags are the building’s share of the regional reliability charge. In PJM, the Peak Load Contribution (PLC) is set by the building’s draw during the five highest grid-wide peak hours of the prior summer, and it sets the capacity charge for the entire following year. New York’s ICAP tag and New England’s capacity tag work the same way. Those charges have cleared at the regulatory price cap in three consecutive PJM auctions, and the cap itself runs through the 2029/30 delivery year.

A battery is dispatchable. It discharges at the moment the demand meter would otherwise set a new monthly peak, and it discharges into the specific afternoons that set the capacity tag. At $10 to $30 per kilowatt-month, each kilowatt of peak it removes is worth $120 to $360 a year in demand charges alone, every year, before capacity savings are counted.

Solar makes the building buy less electricity. Storage makes the electricity it still buys cheaper.

The state programs that pay batteries to perform

Federal credit aside, the Northeast states Plankton Energy serves either pay storage directly or are building a program to do it.

Massachusetts runs the most mature pair: ConnectedSolutions pays a per-kilowatt rate for summer peak discharge, and Clean Peak Energy Certificates pay for discharge during defined seasonal peak windows. SMART 3.0 also requires larger solar projects to pair with storage unless an exemption applies, which makes pairing a design requirement for many Massachusetts projects.

Connecticut’s Energy Storage Solutions program, administered through the Green Bank and the utilities, pays an enrollment incentive plus performance payments for dispatching into summer and winter peak events over ten years. It can be paired with the state’s NRES solar tariff.

New York offers a retail storage incentive through NYSERDA for distribution-connected systems, and New York City’s Local Law 97 gives on-site storage compliance value toward a building’s emissions limit, which matters for many New York commercial properties.

New Jersey is the one to watch. The Garden State Energy Storage Program, launched by Board of Public Utilities order in June 2025 under the state’s 2,000-megawatt storage mandate, has two phases. Phase 1 awarded 355 megawatts of transmission-scale projects in its first tranche, and a second tranche of 645 megawatts opened in March 2026. Phase 2, the distributed phase, has not opened. The Board’s August 2026 straw proposal covers a first block of about 150 megawatts focused on residential batteries, paid through performance-based payments over ten years; commercial storage is slated for later blocks, and no incentive values have been published. Incentive programs of this kind tend to fill quickly when they open. New Jersey owners who want a commercial block incentive should have a sized, interconnection-ready project before the block is defined, not after.

What the grid is telling you

The same shortage that is pushing capacity prices to the cap is making storage the resource grid operators actually want. Solar and battery storage accounted for 91% of new grid capacity added in the first quarter of 2026, because they can be built on a timeline that matches the demand curve.

For a building owner, that is a signal about where rate design is going. Utilities and grid operators are moving toward tariffs that reward flexibility (time-of-use energy rates, steeper demand charges, peak-window incentives) because flexibility is what the grid is short of. A building with storage is positioned on the right side of those changes. A building without it is the load everyone else is being paid to offset.

How storage fits the 2027 decision

Two cases cover most owners.

Owners building solar now. A project racing the December 31, 2027 placed-in-service date can add storage to the same interconnection and the same roof. The solar earns its credit on the 2027 deadline; the battery earns its own credit on the 2033 timeline. The pairing also improves the solar project’s economics directly. Storage captures midday production the building cannot use and shifts it into the afternoon peak that sets demand charges, and it reduces the curtailment and export-rate risk that comes with oversizing an array.

Owners who already have solar, or who missed the window. A standalone battery qualifies for Section 48E on its own. For a building that installed solar in the credit era, storage is a second, independent federal incentive attached to the bill lines the array left untouched. For a building that cannot make 2027, it is the federal incentive still on the table alongside permanent 100% bonus depreciation and the state incentive stack that carries post-ITC solar economics.

In both cases the sequencing rule from the solar side holds: interconnection first, because a storage interconnection in a congested Northeast distribution network is its own study, and because state incentive blocks reward projects that are ready when they open.

Where storage does not pencil

Storage is a load-profile investment, not a universal one. A building on a flat, energy-only tariff with low demand charges has little for a battery to attack. A building with a flat load gains less than one with sharp peaks. Fire and building codes (UL 9540A testing, NFPA 855 siting) constrain where a battery can sit, and some roofs and electrical rooms cannot accommodate one without upgrades. Batteries also degrade; a 15-year pro forma should carry an augmentation reserve. The right answer comes from fifteen-minute interval data and the actual tariff, which is why Plankton Energy models storage on the building’s metered load before it proposes one, under direct ownership or a third-party structure.

Congress kept one federal energy credit alive past 2027. It kept the one that works on the part of the utility bill that is rising fastest. That is not a bad place to put capital.

Frequently asked questions

Does battery storage still qualify for the federal tax credit in 2026?

Yes. Energy storage, standalone or paired with solar, remains eligible for the 30% Section 48E Investment Tax Credit for projects beginning construction through 2033, phasing down to 75% in 2034 and 50% in 2035. OBBBA terminated the solar credit on a 2027 schedule but left storage on a longer timeline.

What are demand charges and how does a battery reduce them?

Demand charges are billed per kilowatt based on a building’s single highest 15-minute draw each month, often $10 to $30 per kilowatt-month on Northeast commercial tariffs. A battery discharges at the moment the building would otherwise set a new peak, cutting the measured maximum. At those rates, each kilowatt removed is worth $120 to $360 a year in demand charges alone.

Can I add a battery to an existing commercial solar system and get a tax credit?

Yes. A standalone storage system qualifies for Section 48E on its own, independent of when the solar was installed or whether the solar claimed a credit. It is a second federal incentive attached to the demand and capacity charges the solar array does not reach.

What is New Jersey’s Garden State Energy Storage Program?

A state program launched in 2025 to help reach New Jersey’s target of 2,000 megawatts of storage by 2030. Phase 1 covers transmission-scale projects. Phase 2, the distributed phase, has not opened: an August 2026 straw proposal covers a first block focused on residential batteries, with commercial storage slated for later blocks and no incentive values published yet.

Does storage make sense without solar?

For buildings with sharp load peaks on tariffs with meaningful demand charges or capacity tags, yes. Standalone storage earns the federal credit and attacks those charges directly. For buildings with flat loads on energy-only tariffs, the economics are weaker. The answer depends on interval meter data and the actual rate schedule.


About Plankton Energy. Plankton Energy develops, engineers, installs, owns and operates commercial solar and battery storage systems across New Jersey, New York, New England and California. Every storage proposal is built from the building’s fifteen-minute interval data and actual tariff, so owners can see exactly which demand and capacity charges a battery removes and what the federal credit and state programs contribute. To find out whether storage pencils on your building, contact Plankton Energy for a load-profile assessment.

Disclaimer: This article is for general informational purposes and does not constitute tax, legal, or investment advice. Federal credit rules, state program terms and incentive levels change; verify current program status before making investment decisions and consult a qualified tax professional.